Safety relay modules and sensors
Using safety relay modules, you can reliably implement safety functions in machines and systems. They monitor signals from emergency stop buttons, light grids, and safety door switches, and initiate a safe state where necessary. The PSR product range comprises safety relays with fixed or configurable safety functions, zero-speed and over-speed safety relays, and safe coupling relays.
Product Search
PSR-SCP- 24UC/ESA4/2X1/1X2
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 2-channel operation, 2 enabling current paths, nominal input voltage: 24 V DC, plug-in screw terminal block
View Product
PSR-MS40-1NO-1DO-24DC-SC
Safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic start, 1 enabling current path, U<sub>S</sub> = 24 V DC, fixed screw terminal block
View Product
PSR-MM25-1NO-2DO-24DC-SP
Safety relay module for sensor-free zero-speed monitoring for 3- and 1-phase motors up to SIL 3, Cat. 3, PL e, 2-channel evaluation of the residual voltage of AC, three-phase, and DC motors, plug-in Push-in terminal block, width: 12.5 mm
View Product
PSR-PLC21-2CO-24DC-SC
Safe coupling relay with force-guided contacts, electrically isolated, 2 changeover contacts, 1-channel, fixed screw terminal block, width: 14 mm
View Product
PSR-ME20-3NO-1NC-24DC-SC
Safety relay for emergency stops, safety doors, and light grids up to SIL 2, Cat. 3, PL d, 1- or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, 1 signaling current path, U<sub>S</sub> = 24 V DC, plug-in screw terminal block
View Product
PSR-SPP- 24DC/FSP2/2X1/1X2
Safe coupling relay for SIL 2 high and low demand applications, coupled digital output signals to the I/O, 2 enabling current paths, 1 signal contact, module for safe state off applications, integrated test pulse filter, width: 17.5 mm, pluggable Push-in terminal block
View Product
PSR-ESS-M2-H110-2000-A
Emergency stop switch in IP65 housing, in conjunction with appropriate evaluation unit suitable for use up to PL e (EN ISO 13849-1), SIL 3 (EN IEC 62061), surface installation, 5-pos. M12 connection
View Product
PSR-SCP- 24UC/ESM4/3X1/1X2/B
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 2-channel operation, 3 enabling current paths, nominal input voltage: 24 V DC, plug-in screw terminal block
View Product
PSR-MS35-1NO-24DC-SC
Safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, U<sub>S</sub> = 24 V DC, fixed screw terminal block
View Product
PSR-SCP- 24UC/ESAM4/2X1/1X2
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 2-channel operation, 2 enabling current paths, nominal input voltage: 24 V DC, plug-in screw terminal block
View Product
PSR-SCP-230UC/ESAM4/3X1/1X2/B
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, 1- or 2-channel operation, 3 enabling current paths, nominal input voltage: 230 V AC/DC, plug-in screw terminal blocks
View Product
PSR-SCP- 24UC/URM/5X1/2X2
Safe coupling relay with force-guided contacts, 5 N/O contacts, 2 N/C contacts, 1-channel, plug-in screw terminal block, width: 22.5 mm
View Product
PSR-SCP- 24UC/URM/5X1/1X2
Safe coupling relay with force-guided contacts, 5 N/O contacts, 1 N/C contact, plug-in screw terminal block, width: 22.5 mm
View Product
PSR-MC73-5NO-1DO-24DC-SP
Safety relay for emergency stop, safety doors, light grids up to SIL 3, Cat. 4, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, off-/on delay of 0.2 s to 300 s, 5 enabling current paths, U<sub>S</sub> = 24 V DC, plug-in Push-in terminal block
View ProductGet in touch with us today, phone 03 6380 2400 or email sales@temtrol.com.au
(License No: 942730)
Copyright TEMTROL TECHNOLOGIES © All Rights Reserved. Website by I saw a Platypus.